1 Zone High Sensitivity Cable

One Zone water leak detection cable provides a solution for highly sensitive applications

1 Zone High Sensitivity Cable
Detection cableproduct type
Andel Floodline®product range
1ZHSCproduct code

A solution for highly sensitive applications

The unique construction of the One Zone High Sensitivity cable has 2 cores twisted around a central former, wrapped in an absorbent layer and covered with a mesh outer braid. It provides a solution for highly sensitive applications — particularly being cable-tied directly to the underside of pipework.

The start and end points of the cable are provided by either traditional Floodline® junction boxes or the Plug And Play system. The zones can be any length, but the typical length is between 5 and 15 metres.

Benefits at a glance

Unique construction

Suitable for highly sensitive applications

Variable lengths available, typically 5 to 15 metres

Can be wetted and dried multiple times

Quick and easy installation

Tough nylon outer braid

Reusable

The sensor can be wetted and dried any number of times, provided the cable is not contaminated with a substance that permanently changes its electrical characteristics. If the contamination is soluble, the cable can be removed, washed (clean water only), dried and returned to use, subject to the level of contamination.

Standards tested and met

CPR (Construction Products Regulation) testing — under the harmonised European standard EN 50575, this cable has been tested for heat release, smoke production and flame spread in accordance with EN 60332-1-2:2004+A11:2016.

Tested under AVCP (Assessment and Verification of Constancy of Performance) system 3 by a notified body, the cable was classified as Euroclass Eca.

An undetected leak can shut down a data centre.

Or close a hospital ward, or trigger a legal claim. Catching it early is always cheaper than the alternative.

Andel Floodline doesn’t just prevent damage. It demonstrates due diligence. Insurers increasingly expect leak detection in high-risk environments, and early warning systems materially reduce premiums, claims exposure and litigation risk.

  • The Shard
  • Houses of Parliament
  • Canary Wharf
  • London 2012 Olympics

No handoff, no gaps, one number to call.

The detail.

Product code: 1ZHSC.

Standards: EN 50575, EN 60332-1-2:2004+A11:2016.

Specification
  • Applications Below raised floors; above suspended ceilings; run in drip trays; laid around the base of plant, apparatus or tank; laid in loops or a wave pattern for general monitoring of larger areas; attached directly to the underside of pipework
  • Detection Activates with any conductive liquid anywhere along the entire length of the detection cable; once dry, can be returned to use
  • Construction 2 core — HFLSF core insulation, polyester fabric wrap, nylon outer braid
  • Dimensions 5mm diameter
  • Fixing Use standard 6mm tower clips, self-adhesive clips or tie-wraps; detection cable is laid loosely with special caution; tags attached at regular intervals to identify zone
Floodline® 1 Zone High Sensitivity Cable — with an absorbent layer and tough nylon outer braid.
Floodline® 1 Zone High Sensitivity Cable — with an absorbent layer and tough nylon outer braid.

Explore the range.

Andel office team outside the head office

Talk to Andel engineers about leak detection.

Specifying at design stage? Learn how to specify leak detection correctly with an accredited CPD session, delivered by Andel engineers.