Floodline® Miulti-8 High-Sensitivity Detection Cable

Floodline® Miulti-8 High-Sensitivity Detection Cable

Enhanced multi-zone cable for sensitive environments

The cable has a fine multi-filament cellulosic outer covering that draws liquid into detection cores, allowing the system to react to the smallest amount of water, conductive liquid and condensation. Miulti-8 High-Sensitivity Detection Cable provides visual evidence of where and when the cable is wet.

One length of cable provides up to eight separately reporting zones. The zone changeover points along the cable are provided by Floodline® junction boxes. The cable is available in any length to provide as much coverage as required, typically between 5 metres and 15 metres.

The cable can be attached to the underside of pipes, inside or outside lagging, laid in drip trays and catchment troughs and fixed to soffits and ceilings. The cable is activated by contact with any conductive liquid anywhere along its entire length. The cable can be wet and dried any number of times and returned to use.

Request your quote

Floodline® Miulti-8 High-Sensitivity Detection Cable

Floodline® 8-Zone High-Sensitivity Cable can connect to any Floodline® zonal control panel or unit either directly or via leader cable.

Standards tested and met: CPR (Construction Products Regulation) Testing

Under the harmonised European standard EN 50575 this cable has been tested for heat release, smoke production and flame spread in accordance with EN 60332-1- 2:2004+A11:2016.

10 year warranty
Customers can enjoy the additional comfort of a 10-year warranty on all Floodline® leak detection products when subscribed to the Andel Service and Maintenance Plan. Please ask for details.

Technical data

Component Specification Details
General Product Type Multi-Zone, High-Sensitivity Water-Sensitive Leak Detection Cable
Purpose Detects the presence of even the smallest amount of water (e.g., condensation) and conductive liquids, providing up to eight separately reporting detection zones from a single cable
Zone Configuration Allows up to eight individual zones from one physical cable run
Typical Zone Lengths Zones can be of any length, but typically between 5 metres and 15 metres
Applications Suited to highly sensitive areas where early detection of minute water ingress is critical, such as data centres, server rooms, clean rooms, control panels, high-value asset protection, under raised floors, above suspended ceilings, roofs, pipes, around the base of equipment and tanks, drip trays, and storage areas
Detection Principle Activates with any conductive liquid, even in minute quantities
Resettability Can be wet and dried any number of times; reusable if not contaminated with a substance that permanently alters its electrical characteristics (can be washed with clean water if contamination is soluble)
Durability Tough, flexible, lightweight, and quick-drying construction
Compatibility Connects to any Floodline® zonal control panel or unit (e.g., Multi-Zone Control Panel, HLD Control Panel) either directly or via leader cable
Benefits High-sensitivity detection, multi-zone reporting from a single cable, high performance, easy to install and maintain, quick drying, reusable, provides early warning of minor leaks
Warranty 10-year warranty (when subscribed to the Andel Service and Maintenance Plan)
Construction Material All polymeric, low smoke and fume, zero halogen construction; often includes an absorbent outer braid for enhanced sensitivity
Diameter Approximately 5mm
Zone Changeover Zone changeover points along the cable are provided by either traditional Floodline 8-zone junction boxes or the Plug and Play Auto-Connect system
Compliance Fire Performance (EN 50575) Tested for heat release, smoke production, and flame spread in accordance with EN 50399:2011+A1:2016 and EN 60332-1-2:2004+A11:2016
Euroclass Classification Classified as Euroclass Dca-s2,d0 (for standard Multi-8, but High-Sensitivity versions may also be Eca depending on specific construction)

Frequently asked questions


It's a multi-zone, water-sensitive cable designed to provide up to eight separately reporting leak detection zones from a single cable length.

It's designed to detect water and conductive liquids at any point along its entire length with enhanced sensitivity.

The primary information available suggests it's for water leak detection.

Yes, it can be wetted and dried multiple times, provided it's not contaminated with substances that permanently alter its electrical characteristics. If soluble contamination occurs, it can be washed, dried, and reused.

Zone changeover points are provided by traditional Floodline 8-zone junction boxes or Andel's Plug And Play system.

It's available in various lengths, typically between 5 metres and 15 metres per zone.

It complies with stringent fire, smoke, and halogen tests under European fire performance requirements (e.g., EN 50575, classified as Euroclass Dca-s2,d0 or Eca depending on the version).

Customers can receive a 10-year warranty on all Floodline leak detection products when subscribed to the Andel Service and Maintenance Plan.